Ion beam analysis

Ion beam analysis

Ion beam analysis ("IBA") is an important family of modern analytical techniques involving the use of MeV ion beams to probe the composition and obtain elemental depth profiles in the near-surface layer of solids. All IBA methods are highly sensitive and allow the detection of elements in the sub-monolayer range. The depth resolution is typically in the range of a fewnanometers to a few ten nanometers. Atomic depth resolution can be achieved, but requires special equipment. The analyzed depth ranges from a few ten nanometers to a few ten micrometers. IBA methods are always quantitative with an accuracy of a few percent. Channeling allows to determine the depth profile of damage in single crystals.

*RBS: Rutherford backscattering is sensitive to heavy elements in a light matrix
*ERD: Elastic recoil detection is sensitive to light elements in a heavy matrix
*PIXE: Particle induced X-ray emission gives the trace and minor elemental composition
*NRA: Nuclear reaction analysis is sensitive to particular isotopes
* Channelling: The fast ion beam can be aligned accurately with major axes of single crystals; then the strings of atoms "shadow" each other and the backscattering yield falls dramatically. Any atoms off their lattice sites will give visible extra scattering. Thus damage to the crystal is visible, and point defects (interstitials) can even be distinguished from dislocations.

The quantitative evaluation of IBA methods requires the use of specialized simulation and data analysis software. SIMNRA and DataFurnace are popular programs for the analysis of RBS, ERD and NRA, while GUPIX is popular for PIXE.

IBA is an area of active research. The last major international scientific conference devoted to IBA (Hyderabad, 2007) was published in Nuclear Instruments and Methods B, volume 266(8).

External links

* Bi-annual scientific conference devoted to IBA: the latest was in [http://www.uohyd.ernet.in/iba2007/ Hyderabad] in September 2007. The next in this series (19th) will be held in [http://www.iop.org/Conferences/Forthcoming_Institute_Conferences/IonBeamAnalysis/event_29233.html/ Cambridge] in September 2009
* [http://ees.elsevier.com/nimb/ "Nuclear Instruments and Methods"] : The international peer reviewed scientific journal largely devoted to IBA developments and applications
* [http://www.rzg.mpg.de/~mam/ SIMNRA] program for the simulation and analysis of RBS, ERD and NRA
* [http://www.ee.surrey.ac.uk/IBC/ndf/ DataFurnace] program for the simulation and analysis of RBS, ERD, NRA, PIXE and PIGE
* [http://www.itn.pt/facilities/lfi/ndf/uk_lfi_ndf.htm/ NDF] free version of NDF (the calculation engine underlying DataFurnace) for the simulation of RBS, ERD and NRA
* [http://pixe.physics.uoguelph.ca/gupix/ GUPIX] program for the simulation and analysis of PIXE


Wikimedia Foundation. 2010.

Игры ⚽ Нужен реферат?

Look at other dictionaries:

  • Ion beam — An ion beam is a type of particle beam consisting of ions. Ion beams have many uses in electronics manufacturing (principally ion implantation) and other industries. Today s ion beam sources are typically derived from the mercury vapor thrusters… …   Wikipedia

  • Ion Beam Mixing — is a process for adhering two multilayers, especially a substrate and deposited surface layer. The process involves bombarding layered samples with doses of ion radiation in order to promote mixing at the interface, and generally serves as a… …   Wikipedia

  • Focused ion beam — Focused ion beam, also known as FIB, is a technique used particularly in the semiconductor and materials science fields for site specific analysis, deposition, and ablation of materials. The FIB is a scientific instrument that resembles a… …   Wikipedia

  • Focused-Ion-Beam-Mikroskop — Foto eines FIB Arbeitsplatzes Ein Focused Ion Beam (Abk.: FIB; englisch für „fokussierter Ionenstrahl“) ist ein Gerät zur Oberflächenanalyse und bearbeitung. Steht der Materialabtrag im Vordergrund, heißt das Verfahren auch Ionendünnung. Wenn die …   Deutsch Wikipedia

  • Ion source — An ion source is an electro magnetic device that is used to create charged particles. These are used primarily within mass spectrometers or particle accelerators.Mass spectrometry In mass spectrometry, an ion source is a piece of equipment used… …   Wikipedia

  • Ion thruster — An ion thruster is a form of electric propulsion used for spacecraft propulsion that creates thrust by accelerating ions. Ion thrusters are characterized by how they accelerate the ions, using either electrostatic or electromagnetic force.… …   Wikipedia

  • Ion — Cation and Anion redirect here. For the particle physics/quantum computing concept, see Anyon. For other uses, see Ion (disambiguation). Hydrogen atom (center) contains a single proton and a single electron. Removal of the electron gives a cation …   Wikipedia

  • List of materials analysis methods — List of materials analysis methods: Contents: Top · 0–9 · A B C D E F G H I J K L M N O P Q R S T U V W X Y Z μSR see Muon spin spectroscopy …   Wikipedia

  • analysis — /euh nal euh sis/, n., pl. analyses / seez /. 1. the separating of any material or abstract entity into its constituent elements (opposed to synthesis). 2. this process as a method of studying the nature of something or of determining its… …   Universalium

  • surface analysis — ▪ chemistry Introduction       in analytical chemistry (chemistry), the study of that part of a solid that is in contact with a gas or a vacuum. When two phases of matter are in contact, they form an interface. The term surface is usually… …   Universalium

Share the article and excerpts

Direct link
Do a right-click on the link above