Fabry–Pérot interferometer

Fabry–Pérot interferometer
Interference fringes, showing fine structure, from a Fabry–Pérot etalon. The source is a cooled deuterium lamp.

In optics, a Fabry–Pérot interferometer or etalon is typically made of a transparent plate with two reflecting surfaces, or two parallel highly reflecting mirrors. (Technically the former is an etalon and the latter is an interferometer, but the terminology is often used inconsistently.) Its transmission spectrum as a function of wavelength exhibits peaks of large transmission corresponding to resonances of the etalon. It is named after Charles Fabry and Alfred Perot.[1] "Etalon" is from the French étalon, meaning "measuring gauge" or "standard".[2]

The resonance effect of the Fabry–Pérot interferometer is identical to that used in a dichroic filter. That is, dichroic filters are very thin sequential arrays of Fabry–Pérot interferometers, and are therefore characterised and designed using the same mathematics.

Etalons are widely used in telecommunications, lasers and spectroscopy to control and measure the wavelengths of light. Recent advances in fabrication technique allow the creation of very precise tunable Fabry–Pérot interferometers.

Contents

Theory

A Fabry–Pérot etalon. Light enters the etalon and undergoes multiple internal reflections.

The varying transmission function of an etalon is caused by interference between the multiple reflections of light between the two reflecting surfaces. Constructive interference occurs if the transmitted beams are in phase, and this corresponds to a high-transmission peak of the etalon. If the transmitted beams are out-of-phase, destructive interference occurs and this corresponds to a transmission minimum. Whether the multiply reflected beams are in phase or not depends on the wavelength (λ) of the light (in vacuum), the angle the light travels through the etalon (θ), the thickness of the etalon () and the refractive index of the material between the reflecting surfaces (n).

The phase difference between each succeeding reflection is given by δ:[3]

\delta = \left( \frac{2 \pi}{\lambda} \right) 2 n \ell \cos\theta.

If both surfaces have a reflectance R, the transmittance function of the etalon is given by

T_e = \frac{(1-R)^2}{1+R^2-2R\cos\delta}=\frac{1}{1+F\sin^2(\delta/2)},

where

 F = \frac{4R}{{(1-R)^2}}

is the coefficient of finesse.

The transmission of an etalon as a function of wavelength. A high-finesse etalon (red line) shows sharper peaks and lower transmission minima than a low-finesse etalon (blue).

Maximum transmission (Te = 1) occurs when the optical path length difference (2nlcos θ) between each transmitted beam is an integer multiple of the wavelength. In the absence of absorption, the reflectance of the etalon Re is the complement of the transmittance, such that Te + Re = 1. The maximum reflectivity is given by:

R_\max = 1-\frac{1}{1+F}= \frac {4R}{(1+R)^2}

and this occurs when the path-length difference is equal to half an odd multiple of the wavelength.

Finesse as a function of reflectivity. Very high finesse factors require highly reflective mirrors.

The wavelength separation between adjacent transmission peaks is called the free spectral range (FSR) of the etalon, Δλ, and is given by:

\Delta\lambda = \frac{ \lambda_0^2}{2n\ell \cos\theta + \lambda_0 } \approx \frac{ \lambda_0^2}{2n\ell \cos\theta }

where λ0 is the central wavelength of the nearest transmission peak. The FSR is related to the full-width half-maximum, δλ, of any one transmission band by a quantity known as the finesse:

 \mathcal{F} = \frac{\Delta\lambda}{\delta\lambda}=\frac{\pi}{2 \arcsin(1/\sqrt F)}.

This is commonly approximated (for R > 0.5) by

 \mathcal{F} \approx \frac{\pi \sqrt{F}}{2}=\frac{\pi R^{1/2} }{1-R}

Etalons with high finesse show sharper transmission peaks with lower minimum transmission coefficients. In the oblique incidence case, the finesse will depend on the polarization state of the beam, since the value of "R", given by the Fresnel equations, is generally different for p and s polarizations.

A Fabry–Pérot interferometer differs from a Fabry–Pérot etalon in the fact that the distance between the plates can be tuned in order to change the wavelengths at which transmission peaks occur in the interferometer. Due to the angle dependence of the transmission, the peaks can also be shifted by rotating the etalon with respect to the beam.

Fabry–Pérot interferometers or etalons are used in optical modems, spectroscopy, lasers, and astronomy.

A related device is the Gires–Tournois etalon.

Detailed analysis

Fabry Perot Diagram1.png

Two beams are shown in the diagram at the right, one of which (T0) is transmitted through the etalon, and the other of which (T1) is reflected twice before being transmitted. At each reflection, the amplitude is reduced by \sqrt R and the phase is shifted by π, while at each transmission through an interface the amplitude is reduced by \sqrt T. Assuming no absorption, conservation of energy requires T + R = 1. In the derivation below, n is the index of refraction inside the etalon, and n0 is that outside the etalon. The incident amplitude at point a is taken to be one, and phasors are used to represent the amplitude of the radiation. The transmitted amplitude at point b will then be

t_0 = T\,e^{ik\ell/\cos\theta},

where k = 2πn / λ is the wavenumber inside the etalon and λ is the vacuum wavelength. At point c the transmitted amplitude will be

TR\,e^{2\pi i + 3ik\ell/\cos\theta}.

The total amplitude of both beams will be the sum of the amplitudes of the two beams measured along a line perpendicular to the direction of the beam. The amplitude at point b can therefore be added to an amplitude t1 equal in magnitude to the amplitude at point c, but retarded in phase by an amount k0 ℓ0 where k0 = 2πn0 / λ is the wavenumber outside of the etalon. Thus

t_1 = RT\,e^{2\pi i+3ik\ell/\cos\theta-ik_0 \ell_0},

where ℓ0 is

\ell_0=2\ell\tan\theta\sin\theta_0\,.

Neglecting the phase change due to the two reflections, the phase difference between the two beams is

\delta={2k\ell\over\cos\theta} - k_0 \ell_0\,.

The relationship between θ and θ0 is given by Snell's law:

n\sin\theta=n_0\sin\theta_0\,,

so that the phase difference may be written:

\delta=2k\ell\,\cos\theta\,.

To within a constant multiplicative phase factor, the amplitude of the mth transmitted beam can be written as:

t_m=TR^m e^{im\delta}\,.

The total transmitted amplitude is the sum of all individual beams' amplitudes:

t=\sum_{m=0}^\infty t_m=T\sum_{m=0}^\infty R^m\,e^{im\delta}

The series is a geometric series whose sum can be expressed analytically. The amplitude can be rewritten as

t=\frac{T}{1-Re^{i\delta}}.

The intensity of the beam will be just t times its complex conjugate. Since the incident beam was assumed to have an intensity of one, this will also give the transmission function:

T_e=tt^*=\frac{T^2}{1+R^2-2R\cos\delta}

Another expression for the transmission function

Defining γ = ln(1 / R) the above expression may be written as:

T_e=\frac{T^2}{1-R^2}\left(\frac{\sinh\gamma}{\cosh\gamma-\cos\delta}\right)

The second term is proportional to a wrapped Lorentzian distribution so that the transmission function may be written as a series of Lorentzian functions:

T_e=\frac{2\pi\,T^2}{1-R^2}\,\sum_{\ell=-\infty}^\infty L(\delta-2\pi\ell;\gamma)

where

L(x;\gamma) = \frac{\gamma}{\pi(x^2+\gamma^2)}

Applications

A picture of the solar corona taken with the LASCO C1 coronagraph which employed a tunable Fabry–Pérot interferometer to recover scans of the solar corona at a number of wavelengths near the FeXIV green line at 5308 Å. The picture is a color coded image of the doppler shift of the line, which may be associated with the coronal plasma velocity towards or away from the satellite camera. In calculating the velocity, the velocity due to solar rotation has been subtracted.
A commercial Fabry-Perot device
  • The most important common applications are as dichroic filters, in which a series of etalonic layers are deposited on an optical surface by vapor deposition. These optical filters usually have more exact reflective and pass bands than absorptive filters. When properly designed, they run cooler than absorptive filters because they can reflect unwanted wavelengths. Dichroic filters are widely used in optical equipment such as light sources, cameras and astronomical equipment.
  • Telecommunications networks employing wavelength division multiplexing have add-drop multiplexers with banks of miniature tuned fused silica or diamond etalons. These are small iridescent cubes about 2 mm on a side, mounted in small high-precision racks. The materials are chosen to maintain stable mirror-to-mirror distances, and to keep stable frequencies even when the temperature varies. Diamond is preferred because it has greater heat conduction and still has a low coefficient of expansion. In 2005, some telecommunications equipment companies began using solid etalons that are themselves optical fibers. This eliminates most mounting, alignment and cooling difficulties.
  • An optical wavemeter is a combination of up to five Fabry–Pérot interferometers with a factor of ten difference in Δλ between any two of them. The beam is made divergent by a cylindrical lens and the distance between two bright lines is recorded by means of a CCD camera.
  • Laser resonators are often described as Fabry–Pérot resonators, although for many types of laser the reflectivity of one mirror is close to 100%, making it more similar to a Gires–Tournois interferometer. Semiconductor diode lasers sometimes use a true Fabry–Pérot geometry, due to the difficulty of coating the end facets of the chip.
  • Etalons are used to construct single-mode lasers. Without an etalon, a laser will generally produce light over a wavelength range corresponding to a number of cavity modes, which are similar to Fabry–Pérot modes. Inserting an etalon into the laser cavity, with well-chosen finesse and free-spectral range, can suppress all cavity modes except for one, thus changing the operation of the laser from multi-mode to single-mode.
  • A Fabry–Pérot etalon can be used to make a spectrometer capable of observing the Zeeman effect, where the spectral lines are far too close together to distinguish with a normal spectrometer.
  • In astronomy an etalon is used to select a single atomic transition for imaging. The most common is the H-alpha line of the sun. The Ca-K line from the sun is also commonly imaged using etalons.
  • In gravitational wave detection, a Fabry–Pérot cavity is used to store photons for almost a millisecond while they bounce up and down between the mirrors. This increases the time a gravitational wave can interact with the light, which results in a better sensitivity at low frequencies. This principle is used by detectors such as LIGO and Virgo, which consist of a Michelson interferometer with a Fabry–Pérot cavity with a length of several kilometers in both arms. Smaller cavities, usually called mode cleaners, are used for spatial filtering and frequency stabilization of the main laser.

See also

Notes and references

  1. ^ Perot frequently spelled his name with an accent—Pérot—in scientific publications, and so the name of the interferometer is commonly written with the accent. Métivier, Françoise (September–October 2006). "Jean-Baptiste Alfred Perot" (in French) (pdf). Photoniques (no. 25). http://www.sabix.org/documents/perot.pdf. Retrieved 2007-10-02.  Page 2: "Pérot ou Perot?"
  2. ^ Oxford English Dictionary
  3. ^ Lipson, S.G.; Lipson, H.; Tannhauser, D.S. (1995). Optical Physics (3rd ed.). London: Cambridge U.P.. pp. 248. ISBN 0521069262. 
  • Hernandez, G. (1986). Fabry–Pérot Interferometers. Cambridge: Cambridge University Press. ISBN 0521322383. 

External links


Wikimedia Foundation. 2010.

Игры ⚽ Нужно решить контрольную?

Look at other dictionaries:

  • Fabry-Pérot-Interferometer —   [fa bri pe ro , nach C. Fabry und A. Pérot], ein Interferometer aus zwei gegeneinander verschiebbaren, ebenen, leicht keilförmigen (Keilwinkel 0,5º) Glas oder Quarzplatten, deren (durch dielektrische Vielfachschichten mit Reflexionsvermögen… …   Universal-Lexikon

  • Fabry-Pérot interferometer — In optics, a Fabry Pérot interferometer or etalon is typically made of a transparent plate with two reflecting surfaces, or two parallel highly reflecting mirrors. (Technically the former is an etalon and the latter is an interferometer, but the… …   Wikipedia

  • Fabry-Perot-Interferometer — Transmissionsspektrum eines Fabry Pérot Interferometers für verschiedene Dämpfungswerte α Das Fabry Pérot Interferometer wurde 1897 von den französischen Physikern Charles Fabry und Alfred Pérot entwickelt. Dieses Interferometer besteht aus zwei… …   Deutsch Wikipedia

  • Fabry-Pérot-Interferometer — Skizze eines Fabry Pérot Interferometers …   Deutsch Wikipedia

  • Fabry-Pérot interferometer — Fabri ir Pero interferometras statusas T sritis fizika atitikmenys: angl. Fabry Pérot interferometer vok. Fabry Pérot Interferometer, n rus. интерферометр Фабри Перо, m pranc. interféromètre de Fabry et Pérot, m; interféromètre Fabry Pérot, m …   Fizikos terminų žodynas

  • Fabry-Pérot-Interferometer — Fabri ir Pero interferometras statusas T sritis fizika atitikmenys: angl. Fabry Pérot interferometer vok. Fabry Pérot Interferometer, n rus. интерферометр Фабри Перо, m pranc. interféromètre de Fabry et Pérot, m; interféromètre Fabry Pérot, m …   Fizikos terminų žodynas

  • Fabry-Pérot interferometer — Fabri ir Pero interferometras statusas T sritis Standartizacija ir metrologija apibrėžtis Daugiapluoštis interferometras, sudarytas iš dviejų stiklo arba kvarco plokštelių. atitikmenys: angl. Fabry Pérot interferometer vok. Fabry Pérot… …   Penkiakalbis aiškinamasis metrologijos terminų žodynas

  • Fabry-Pérot-Interferometer — Fabri ir Pero interferometras statusas T sritis Standartizacija ir metrologija apibrėžtis Daugiapluoštis interferometras, sudarytas iš dviejų stiklo arba kvarco plokštelių. atitikmenys: angl. Fabry Pérot interferometer vok. Fabry Pérot… …   Penkiakalbis aiškinamasis metrologijos terminų žodynas

  • Fabry-Pérot interferometer — Fabri ir Pero interferometras statusas T sritis Standartizacija ir metrologija apibrėžtis Interferometras, kurio veikimas pagrįstas daugkartinio bangų atspindžio nuo dviejų lygiagrečių veidrodinių paviršių interferencija. atitikmenys: angl. Fabry …   Penkiakalbis aiškinamasis metrologijos terminų žodynas

  • Fabry-Pérot-Interferometer — Fabri ir Pero interferometras statusas T sritis Standartizacija ir metrologija apibrėžtis Interferometras, kurio veikimas pagrįstas daugkartinio bangų atspindžio nuo dviejų lygiagrečių veidrodinių paviršių interferencija. atitikmenys: angl. Fabry …   Penkiakalbis aiškinamasis metrologijos terminų žodynas

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”