Lockout-Tagout

Lockout-Tagout

, and placing it in such a position that no hazardous power sources can be turned on. The procedure requires that a tag be affixed to the locked device indicating that it should not be turned on.

When two or more subcontractors are working on different parts of a larger overall system, the locked-out device is first secured with a folding scissors clamp that has many padlock holes capable of holding it closed. Each subcontractor applies their own padlock to the clamp. The locked-out device cannot be activated until all workers have signed off on their portion of the project and removed their padlock from the clamp.

In the United States a lock selected by color, shape or size (e.g. red padlock) is used to designate a standard safety device, locking and securing hazardous energy. No two keys or locks should ever be the same. A person's lock and tag must not be removed by anyone other than the individual who installed the lock and tag unless removal is accomplished under the direction of the employer. Employer procedures and training for such removal must have been developed, documented and incorporated into the employer's energy control program. Fact|date=May 2007

Hazardous energy and its isolation

Modern machinery can contain many hazards to workers, from things like electrical, mechanical, pneumatic or hydraulic sources. For example a typical industrial machine may contain things like hot fluids, moving presses, blades, propellors, electrical heaters, conveyor belts with pinch points, moving chains, ultraviolet light, etc.

The National Electric Code states that a safety/service disconnect must be installed within sight of serviceable equipment. The safety disconnect ensures the equipment can be isolated and there is less chance of someone turning the power back on if they can see the work going on. These safety disconnects usually have multiple places for locks so more than one person can work on equipment safely.

Disconnecting or making safe the device is known as isolation. This is accompanied by the tagging of the device to let others know not to de-isolate the device.

In industrial processes it can be difficult to establish where the appropriate danger sources might be. For example a food processing plant may have input and output tanks and high temperature cleaning systems connected, but not in the same room or area of the factory. It would not be unusual to have to visit several areas of the factory in order to effectively isolate a device for service (e.g. device itself for power, upstream material feeders, downstream feeders and control room).

Modern safety manufacturers provide a range of isolation devices specifically designed to fit various switches, valves and effectors. For example most modern circuit-breakers have a provision to have a small padlock attached to prevent their activation. For other devices such as ball or gate valves, plastic pieces which either fit against the pipe and prevent movement, or clam-shell style objects, which completely surround the valve and prevent its manipulation are used.

A common feature of these devices is their bright color, usually red to increase visibility and allow workers to readily see if a device is isolated. Also, the devices are usually of such a design and construction to prevent it being removed with any moderate force. (That is to say that an isolation device does not have to stand up to a chainsaw, but if an operator forcibly removes it, it will be immediately visible that it has been tampered with).

ite polices regarding lockout/tagout

Many sites have the officially stated policy that only the person who tagged the device can untag it. This means that if a worker goes home after their shift without removing the tag from a device which is ready for service, then they will have to travel back to the site to untag it. Giving approval for the removal of a tag over the phone is not an option.

Whilst this policy might make it seem as if it is encouraging workers to take the risk of not tagging out in the first place, it is usually accompanied by a policy stating that operating on a device without tagging it out will result in instant dismissal.

Identification

The tag must have an identification showing the name of the person doing the lock and tag and a contact phone number. Fact|date=May 2007

Industry safety standard in the United States

In industry this is an Occupational Safety and Health Administration (OSHA) standard, as well as for electrical NFPA 70E. OSHA’s standard on the Control of Hazardous Energy (Lockout-Tagout), found in [http://osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9804 CFR 1910.147] , spells out the steps employers must take to prevent accidents associated with hazardous energy. The standard addresses practices and procedures necessary to disable machinery and prevent the release of potentially hazardous energy while maintenance or servicing activities are performed.

Two other OSHA standards also contain energy control provisions: [http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9868 29 CFR 1910.269] and [http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9910 1910.333] . In addition, some standards relating to specific types of machinery contain deenergization requirements such as 29 CFR 1910.179(l)(2)(i)(c)(requiring the switches to be “open and locked in the open position” before performing preventive maintenance on overhead and gantry cranes) [ The standard provides a limited exception to the requirement that energycontrol procedures be documented. If an employer can demonstrate the existence of "each" of the eight elements listed in 1910.147(c)(4)(i), the employer is not required to document the energy control procedure. However, the exception terminates if circumstances change and "any" of the elements no longer exist] . The provisions of Part 1910.147 apply in conjunction with these machine-specific standards to assure that employees will be adequately protected against hazardous energy.

Compliance

If employees service or maintain machines where the unexpected startup, energization, or the release of stored energy could cause injury, the OSHA standard applies. The standard applies to all sources of energy, including, but not limited to: mechanical, electrical, hydraulic, pneumatic, chemical, and thermal energy.

The standard does not cover electrical hazards from work on, near, or with conductors or equipment in electric utilization (premise wiring) installations, which are outlined by [http://www.osha.gov/pls/oshaweb/owastand.display_standard_group?p_toc_level=1&p_part_number=1910#1910_Subpart_S 29 CFR Part 1910 Subpart S] . You can find the specific lockout and tagout provisions for electrical shock and burn hazards in 29 CFR Part 1910.333. Controlling hazardous energy in installations for the exclusive purpose of power generation, transmission, and distribution, including related equipment for communication or metering, is covered by 29 CFR 1910.269.

The standard also does not cover the agriculture, construction, and maritime industries or oil and gas well drilling and servicing. Other standards concerning the control of hazardous energy, however, apply in many of these industries and situations.

Exceptions

The standard does not apply to general industry service and maintenance activities in the following situations, when:

* Exposure to hazardous energy is controlled completely by unplugging the equipment from an electric outlet and where the employee doing the service or maintenance has exclusive control of the plug. This applies only if electricity is the only form of hazardous energy to which employees may be exposed. This exception encompasses many portable hand tools and some cord and plug connected machinery and equipment.

* An employee performs hot-tap operations on pressurized pipelines that distribute gas, steam, water, or petroleum products, for which the employer shows the following:
** Continuity of service is essential;
** Shutdown of the system is impractical; and
** The employee follows documented procedures and uses special equipment that provides proven, effective employee protection.

* The employee is performing minor tool changes or other minor servicing activities that are routine, repetitive, and integral to production, and that occur during normal production operations. In these cases, employees must have effective, alternative protection.

Notes

ee also

* Electrical engineering
* High-voltage hazards
* NFPA 70E

External links

U.S. catalog standards and codes / guideline links

* [http://www.mikeholt.com/technical.php?id=nec/technicalnecfreestuff Mike Holt NEC in the USA]
* [http://www.nfpa.org/catalog/ "NFPA 70E": Electrical Safety in the Workplace, USA]
* [http://www.eh.doe.gov/techstds/standard/hdbk1092/hdbk1092.pdf USA Department of Energy "electrical safety handbook"]
* [http://ehs.ucsc.edu/Safety/ehs.asp?page=Lock-out_Tag-out UCSC Environmental Health & Safety]
* [http://www.cdc.gov/niosh/docs/2002-123/2002-123d.html# NIOSH Electrical Safety - Lock-out/ Tag-out checklist]


Wikimedia Foundation. 2010.

Игры ⚽ Нужна курсовая?

Look at other dictionaries:

  • Lockout — may mean:* Lockout (industry), a work stoppage in which an employer prevents some or all employees from working * Lockout (telecommunication), a system to prevent unwanted signals * A daytime period in some hostels during which guests are… …   Wikipedia

  • Occupational Safety and Health Administration — Not to be confused with EU OSHA, the European Agency for Safety and Health at Work. For other uses, see OSHA (disambiguation). Occupational Safety and Health Administration Agency overview Formed 1970 …   Wikipedia

  • Computerized Maintenance Management System — (CMMS) is also known as Enterprise Asset Management.A CMMS software package maintains a computer database of information about an organization’s maintenance operations. This information is intended to help maintenance workers do their jobs more… …   Wikipedia

  • Claude Akins — Born Claude Marion Akins May 25, 1926 Nelson, Georgia, U.S. Died January 27, 1994(1994 01 27) (aged 67) Altadena …   Wikipedia

  • NFPA 70E — NFPA 70E, titled Standard for Electrical Safety in the Workplace, is a standard of the National Fire Protection Association (NFPA). The document covers electrical safety requirements for employees. The NFPA is best known for its sponsorship of… …   Wikipedia

  • Phillips Disaster — The Phillips Disaster refers to a devastating series of explosions and fire in October of 1989, near the Houston Ship Channel in Texas, USA. The initial blast registered 3.5 on the Richter Scale, and the conflagration took 10 hours to bring under …   Wikipedia

  • Oregon Occupational Safety and Health Administration — (Oregon OSHA) is a government agency of the U.S. state of Oregon. OSHA is a division of the Oregon Department of Consumer and Business Services and operates under a state plan agreement with federal OSHA. [ [http://www.osha.gov/ Federal OSHA] ]… …   Wikipedia

  • Prevention through design — (PtD) is the concept of mitigating occupational hazards by designing them out . This method for reducing workplace safety risks lessens workers reliance on personal protective equipment.National Institute for Occupational Safety and Health. [http …   Wikipedia

  • Arc Flash Loss Prevention — AFLP Arc Flash Loss Prevention is a six step program designed to help businesses and organizations comply with Occupational Safety and Health Administration (OSHA) and National Fire Protection Association (NFPA) requirements for protecting… …   Wikipedia

  • Brady (Unternehmen) — Die Brady Corporation ist ein internationales Herstellungs und Vertriebsunternehmen von Kennzeichnungs und Arbeitssicherheitslösungen für Gebäude, Produkte und Personen. Inhaltsverzeichnis 1 Überblick 2 Das Unternehmen Brady 2.1 Historische Daten …   Deutsch Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”