Thromboelastography

Thromboelastography

Thromboelastography (TEG) is a method of testing the efficiency of coagulation in the blood. It was first developed by the German Dr. Hellmut Hartert at Medical University of Heidelberg. in 1948. It is especially important in surgery and anesthesiology.

The original method

In classical thromboelastography, a small sample of blood (typically 0.36 ml) is placed into a cuvette (cup) which is rotated gently through 4º 45´ (cycle time 6/min) to imitate sluggish venous flow and activate coagulation. When a sensor shaft is inserted into the sample a clot forms between the cup and the sensor. The speed and strength of clot formation is measured in various ways (now usually by computer), and depends on the activity of the plasmatic coagulation system, platelet function, fibrinolysis and other factors which can be affected by illness, environment and medications.

The patterns of changes in strength and elasticity in the clot provides information about how well the blood can perform hemostasis (the halting of blood flow), and how well or poorly different factors are contributing clot formation.

Four values that represent clot formation are determined by this test: the R value (or reaction time), the K value, the angle and the MA (maximum amplitude). The R value represents the speed of clot formation (time until the first evidence of a clot is detected). The K value is the time from the end or R until the clot reaches 20mm and this represents the speed of clot formation. The angle is the tangent of the curve made as the K is reached and offers similar information to K. The MA a reflection of clot strength. A mathematical formula determined by the manufacturer can be used to determine a Coagulation Index (CI) (or overall assessment of coagulability) which takes into account the relative contribution of each of these 4 values into 1 equation. [Donahue SM, Otto CM, Thromboelastography: a tool for measuring hypercoagulability, hypocoagulability, and fibrinolysis, Journal of Veterinary Emergency and Critical Care:15(1), March 2005, Pages: 9-16]

Other methods

Rotation thromboelastometry or ROTEM (the name is a trademark of Pentapharm) is another version in which it is the sensor shaft rather than the cup which rotates. The shaft typically rotates back and forth 4º 45´ (cycle time 10/min). It is connected with a spring to measure elasticity. As the blood in the cuvette begins to clot there is a loss of elasticity in the spring causing changes in the rotation of the shaft. These changes are detected by the light reflected by the small mirror on the shaft and are converted by a transducer to electrical signals which are then measured by a computer.

Pentapharm claims this opto-mechanical detection method makes this method more precise and less vulnerable to vibration and mechanical shocks than the classical method making the transportation and installation of the instrument very simple.

References

* Wenker, Olivier C.; Wojciechowski, Zbigniew; Sheinbaum, Roy; Zisman, Eli. [http://www.ispub.com/ostia/index.php?xmlFilePath=journals/ija/vol1n3/teg.xml "Thrombelastography"] . "The Internet Journal of Anesthesiology". 2000. Volume 1 Number 3.
* Whitten, Charles W. M.D.; Greilich, Philip E. M.D. [http://www.anesthesiology.org/pt/re/anes/fulltext.00000542-200005000-00008.htm;jsessionid=DXjpM23YXtXn5AtNCP0uY1Ln52P3vxF611MSsEekkmXVAAGrg2gl!-287926661!-949856145!9001!-1 "Thromboelastography: Past, Present, and Future"] . "Anesthesiology". 92(5):1226, May 2000.
* [http://www.rotem.de/index.php?id=50&L= Pentapharm GMBH: Thromboelastography]
* [http://vam.anest.ufl.edu/simulations/simulationportfolio.php Free simulation of a thromboelastograph (Requires Registration)]


Wikimedia Foundation. 2010.

Игры ⚽ Нужно решить контрольную?

Look at other dictionaries:

  • thromboelastography — noun A method of testing the efficiency of coagulation in the blood. See Also: thromboelastogram …   Wiktionary

  • thromboelastography — throm·bo·elas·tog·ra·phy (throm″bo e″las togґrə fe) determination of the rigidity of the blood or plasma during coagulation, by use of the thromboelastograph …   Medical dictionary

  • Hemoglobin — Hemoglobin, human, adult (heterotetramer, (αβ)2) Structure of human hemoglobin. The protein s α and β subunits are in red and blue, and the iron containing heme groups in green. Fro …   Wikipedia

  • Coagulation — This article is about blood clotting. For other meanings see Coagulation (disambiguation). Coagulation is a complex process by which blood forms clots. It is an important part of hemostasis, the cessation of blood loss from a damaged vessel,… …   Wikipedia

  • Erythrocyte sedimentation rate — Diagnostics A rack of ESR tubes. MeSH …   Wikipedia

  • Complete blood count — Blood count redirects here. For the Billy Strayhorn composition, see Blood Count. Complete blood count Diagnostics Schematics (also sometimes called Fishbones ) of shorthand for complete blood count commonly used by clinicians and healthcare… …   Wikipedia

  • Hematocrit — Intervention Blood components MeSH …   Wikipedia

  • Mean corpuscular hemoglobin concentration — hemoglobin The mean corpuscular hemoglobin concentration, or MCHC, is a measure of the concentration of hemoglobin in a given volume of packed red blood cells. It is reported as part of a standard complete blood count. It is calculated by… …   Wikipedia

  • Mean corpuscular hemoglobin — The mean corpuscular hemoglobin, or mean cell hemoglobin (MCH), is the average mass of hemoglobin per red blood cell in a sample of blood. It is reported as part of a standard complete blood count. MCH value is diminished in hypochromic… …   Wikipedia

  • Mean corpuscular volume — The mean corpuscular volume, or mean cell volume (MCV), is a measure of the average red blood cell volume that is reported as part of a standard complete blood count. In patients with anemia, it is the MCV measurement that allows classification… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”