Psychrometrics

Psychrometrics

Psychrometrics or psychrometry are terms used to describe the field of engineering concerned with the determination of physical and thermodynamic properties of gas-vapor mixtures. The term derives from the Greek "psuchron" (ψυχρόν) ( [http://www.perseus.tufts.edu/cgi-bin/ptext?doc=Perseus%3Atext%3A1999.04.0057%3Aentry%3D%23115938 cold] ) and "metron" (μέτρον) ( [http://www.perseus.tufts.edu/cgi-bin/ptext?doc=Perseus%3Atext%3A1999.04.0057%3Aentry%3D%2367261 means of measurement] ).

Common applications

The principles of psychrometry apply to any physical system consisting of gas-vapor mixtures. The most common system of interest, however, are mixtures of water vapor and air because of its application in heating, ventilating, and air-conditioning and meteorology.

Psychrometric ratio

The psychrometric ratio is the ratio of the heat transfer coefficient to the product of mass transfer coefficient and humid heat at a wetted surface. It may be evaluated with the following equation [http://www.che.iitb.ac.in/courses/uglab/manuals/coollabmanual.pdf, accessed 20080408] [http://www.probec.org/fileuploads/fl120336971099294500CHAP12_Dryers.pdf, accessed 20080408] :

:r = frac {h_c} {k_y c_s}

:where:::*r = Psychrometric ratio, dimensionless::*h_c = convective heat transfer coefficient, W m-2 K-1::*k_y = convective mass transfer coefficient, kg m-2 s-1::*c_s = humid heat, J kg-1 K-1

Humid heat is the constant-pressure specific heat of moist air, per unit mass of dry air. [http://www.engin.umich.edu/class/che360/coursepack/ch13-cooltower.doc]

The psychrometric ratio is an important property in the area of psychrometrics as it relates the absolute humidity and saturation humidity to the difference between the dry bulb temperature and the adiabatic saturation temperature.

Mixtures of air and water vapor are the most common systems encountered in psychrometry. The psychrometric ratio of air-water vapor mixtures is approximately unity which implies that the difference between the adiabatic saturation temperature and wet bulb temperature of air-water vapor mixtures is small. This property of air-water vapor systems simplifies drying and cooling calculations often performed using psychrometic relationships.

Psychrometric chart

A psychrometric chart is a graph of the physical properties of moist air at a constant pressure (often equated to an elevation relative to sea level). The chart graphically expresses how various properties relate to each other, and is thus a graphical equation of state. The thermophysical properties found on most psychrometric charts are:

:Dry-bulb temperature (DBT) is that of an air sample, as determined by an ordinary thermometer, the thermometer's bulb being dry. It is typically the x-axis, the horizontal axis, of the graph. The SI units for temperature are Celsius; other units are Fahrenheit.:Wet-bulb temperature (WBT) is that of an air sample after it has passed through a constant-pressure, ideal, adiabatic saturation process, that is, after the air has passed over a large surface of liquid water in an insulated channel. In practice, this is the reading of a thermometer whose sensing bulb is covered with a wet sock evaporating into a rapid stream of the sample air. The WBT is the same as the DBT when the air sample is saturated with water. The slope of the line of constant WBT reflects the heat of vaporization of the water required to saturate the air of a given relative humidity.:Dew point temperature (DPT) is that temperature at which a moist air sample at the same pressure would reach water vapor saturation. At this saturation point, water vapor would begin to condense into liquid water fog or (if below freezing) solid hoarfrost, as heat is removed. The dewpoint temperature is measured easily and provides useful information, but is normally not considered an independent property. It duplicates information available via other humidity properties and the saturation curve.:Relative Humidity (RH) is the ratio of the mole fraction of water vapor to the mole fraction of saturated moist air at the same temperature and pressure. RH is dimensionless, and is usually expressed as a percentage. Lines of constant RH reflect the physics of air and water: they are determined via experimental measurement. Note: the notion that air "holds" moisture, or that moisture dissolves in dry air and saturates the solution at some proportion, is an erroneous (albeit widespread) concept (see Relative humidity for further details). :Humidity Ratio (also known as Moisture Content, Mixing Ratio, or Specific Humidity) is the proportion of mass of water vapor per unit mass of dry air at the given conditions (DBT, WBT, DPT, RH, etc.). It is typically the y-axis, the vertical axis, of the graph. For a given DBT there will be a particular humidity ratio for which the air sample is at 100% relative humidity: the relationship reflects the physics of water and air and must be measured. Humidity Ratio is dimensionless, but is sometimes expressed as grams of water per kilogram of dry air or grains of water per pound of air.:Specific Enthalpy symbolized by "h", also called heat content per unit mass, is the sum of the internal (heat) energy of the moist air in question, including the heat of the air and water vapor within. In the approximation of ideal gasses, lines of constant enthalpy are parallel to lines of constant WBT. Enthalpy is given in (SI) joules per kilogram of air or BTU per pound of air.:Specific Volume, also called Inverse Density, is the volume per unit mass of the air sample. The SI units are cubic meters per kilogram of air; other units are cubic feet per pound of dry air.

The versatility of the psychrometric chart lies in the fact that by knowing three independent properties of some moist air (one of which is the pressure), the other properties can be determined. Changes in "state", such as when two air streams mix, can be modeled easily and somewhat graphically using the correct psychrometric chart for the location's air pressure or elevation relative to sea level. For locations at or below 2000 ft (600 m), a common assumption is to use the sea level psychrometric chart.

The relationship between DBT, WBT, and RH is given by the Mollier diagram (pressure-enthalpy) for water in air, developed by Richard Mollier. Willis Carrier, considered the 'father' of modern air-conditioning, rearranged the Mollier diagram for moist air (its "T-s" chart) to allow such graphical solutions. Many variations and improvements to the psychrometric charts have occurred since, and most charts do not show the specific entropy ("s") like the Mollier diagram. ASHRAE now publishes what are considered the modern, standard psychrometric charts, in both I-P and SI units, for a variety of elevations or air pressures.

How to read the chart

The most common chart used by practitioners and students alike is the "ω-t" (omega-t) chart in which the dry bulb temperature (DBT) appears horizontally as the abscissa and the humidity ratios (ω) appear as the ordinates.

In order to use a particular chart, for a given air pressure or elevation, at least two of the six independent properties must be known (DBT, WBT, RH, humidity ratio, specific enthalpy, and specific volume). This gives rise to left({6 atop 2} ight) = 15 possible combinations.

DBT: This can be determined from the abscissa on the x-axis, the horizontal axis

DPT: Follow the horizontal line from the point where the line from the horizontal axis arrives at 100% RH, also known as the "saturation curve".

WBT: Line inclined to the horizontal and intersects saturation curve at DBT point.

RH: Hyperbolic lines drawn asymptotically with respect to the saturation curve which corresponds to 100% RH.

Humidity ratio: Marked on the y-axis.

Specific enthalpy: lines of equal values, or hash marks for, slope from the upper left to the lower right.

Specific volume: Equally spaced parallel family of lines.

Dry-bulb temperature

Common thermometers measure what is known as the dry-bulb temperature. Electronic temperature measurement, via thermocouples, thermistors, and resistance temperature devices (RTDs), for example, have been widely used too since they became available.

Wet-bulb temperature

The thermodynamic wet-bulb temperature is a thermodynamic property of a mixture of air and water vapor. The value indicated by a simple wet-bulb thermometer often provides an adequate approximation of the thermodynamic wet-bulb temperature.

A wet-bulb thermometer is an instrument which may be used to infer the amount of moisture in the air. If a moist cloth wick is placed over a thermometer bulb the evaporation of moisture from the wick will lower the thermometer reading (temperature). If the air surrounding a wet-bulb thermometer is dry, evaporation from the moist wick will be more rapid than if the air is moist. When the air is saturated no water will evaporate from the wick and the temperature of the wet-bulb thermometer will be the same as the reading on the dry-bulb thermometer. However, if the air is not saturated water will evaporate from the wick causing the temperature reading to be lower.

The accuracy of a simple wet-bulb thermometer depends on how fast air passes over the bulb and how well the thermometer is shielded from the radiant temperature of its surroundings. Speeds up to 5,000 ft/min (60 mph) are best but dangerous to move a thermometer at that speed. Errors up to 15% can occur if the air movement is too slow or if there is too much radiant heat present (sunlight, for example).

A wet bulb temperature taken with air moving at about 1-2 m/s is referred to as a screen temperature, whereas a temperature taken with air moving about 3.5 m/s or more is referred to as sling temperature.

A psychrometer is a device that includes both a dry-bulb and a wet-bulb thermometer. A sling psychrometer requires manual operation to create the airflow over the bulbs, but a powered psychrometer includes a fan for this function.

ee also

*Air
*Air conditioning
*Dalton's law of Partial Pressures
*Dew point
*Dry-bulb temperature
*Evaporative cooling
*Humidity
*Relative humidity
*Wet-bulb temperature

References

External links

* [http://www.truetex.com/psychrometric_chart.htm Psychrometric Chart] - Detailed psychrometric chart including curves for enthalpy, air mass, and water mass.
* [http://www.ashrae.org American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.]
* [http://www.uigi.com/technology.html Universal Industrial Gases, Inc. webpage] - Links to physical properties tables, to psychrometric charts that depict inter-relationships among the various physical properties of air, to online psychrometric properties calculators for easy calculation of properties, and to individual gas information pages.
* [http://www.issi1.com/corwin/calculator/vapor.html Corwin's Calculators] Calculator for humidity, dew point.
* Psicro: [http://www.psicro.org] , Psycrhometric calculator: [http://psicro.org/psicrocalc.html] INENCO. UNSa - CONICET [http://www.v2cstudios.com/en/psychrometree.html Psychrometree] , Psychrometric calculator for Linux, Mac and Windows.


Wikimedia Foundation. 2010.

Игры ⚽ Нужно решить контрольную?

Look at other dictionaries:

  • psychrometrics — noun the study of the physical and thermodynamic properties of the atmosphere and its water vapour …   Wiktionary

  • Psychrometrics —   The analysis of atmospheric conditions, particularly moisture in the air …   Energy terms

  • Dew point — The dew point is the temperature to which a given parcel of humid air must be cooled, at constant barometric pressure, for water vapor to condense into liquid water. The condensed water is called dew when it forms on a solid surface. The dew… …   Wikipedia

  • Evaporative cooler — An evaporative cooler, photographed in Rocky Ford, Colorado, used in the drier parts of the American West to provide economical cooling …   Wikipedia

  • Richard Mollier — Not to be confused with Molière. Richard Mollier Richard Mollier (30 November 1863, Triest – 13 March 1935, Dresden) was a German professor of Applied Physics and Mechanics in Göttingen and Dresden, a pioneer of experimental research in… …   Wikipedia

  • ΔT — This article is about the time difference. For the temperature difference, see psychrometrics. ΔT vs. time from 1657 to 1984[1] ΔT, Delta T, delta T, deltaT, or DT is the time difference obtained by subtracting Universal Time (UT) from… …   Wikipedia

  • Steam — In physical chemistry, and in engineering, steam refers to vaporized water. It is a pure, completely invisible gas (for mist see below). At standard temperature and pressure, pure steam (unmixed with air, but in equilibrium with liquid water)… …   Wikipedia

  • Thermodynamics — Annotated color version of the original 1824 Carnot heat engine showing the hot body (boiler), working body (system, steam), and cold body (water), the letters labeled according to the stopping points in Carnot cycle …   Wikipedia

  • Equilibrium — is the condition of a system in which competing influences are balanced and it may refer to:cienceBiology* Equilibrioception, the sense of balance present in humans and animals * Homeostasis, the ability of an open system, especially living… …   Wikipedia

  • Humidity — is the amount of water vapor in the air. In daily language the term humidity is normally taken to mean relative humidity. Relative humidity is defined as the ratio of the partial pressure of water vapor in a parcel of air to the saturated vapor… …   Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”