A regenerative heat exchanger, or more commonly a regenerator, is a type of heat exchanger where the flow through the heat exchanger is cyclical and periodically changes direction. It is similar to a countercurrent heat exchanger. However, a regenerator mixes the two fluid flows while a countercurrent exchanger maintains them separated. The temperature profile remains at a nearly constant temperature, and this includes the fluid entering and exiting each end.

Five Cowper's regenerative heat exchanger placed in series.
Regenerative heat exchangers use counter-current exchange to minimize loss of heat while permitting flow.

In regenerative heat exchangers, the fluid on either side of the heat exchanger is nearly always the same fluid. The fluid is cycled through the heat exchanger, often reaching high temperatures. The fluid may go through an external processing step, and then it is flowed back through the heat exchanger in the opposite direction for further processing. Usually the application will use this process cyclically or repetitively. Thus, in regenerative heat exchangers, a fluid incoming to a process is heated using the energy contained in the fluid exiting this process.

The regenerative heat exchanger gives a considerable net savings in energy, since most of the heat energy is reclaimed nearly in a thermodynamically reversible way. This type of heat exchanger can have a thermal efficiency of over 90%, transferring almost all the relative heat energy from one flow direction to the other. Only a small amount of extra heat energy needs to be added at the hot end, and dissipated at the cold end, even to maintain very high or very low temperatures.

Contents

History

The regenerator was invented by Rev. Robert Stirling in 1816, and is commonly found as a component of his Stirling engine. The simplest Stirlings, and most models, use a less efficient but simpler to construct, displacer instead.

Types of regenerators

In rotary regenerators the matrix rotates continuously through two counter-flowing streams of fluid. In this way, the two streams are mostly separated but the seals are generally not perfect. Only one stream flows through each section of the matrix at a time; however, over the course of a rotation, both streams eventually flow through all sections of the matrix in succession. Each portion of the matrix will be nearly isothermal, since the rotation is perpendicular to both the temperature gradient and flow direction, and not through them. The two fluid streams flow counter-current. The fluid temperatures vary across the flow area; however the local stream temperatures are not a function of time.

In a fixed matrix regenerator, a single fluid stream has cyclical, reversible flow; it is said to flow "counter-current". This regenerator may be part of a valveless system, such as a Stirling engine. In another configuration, the fluid is ducted through valves to different matrices in alternate operating periods Ph and Pc resulting in outlet temperatures that vary with time.

Another type of regenerator is called a micro scale regenerative heat exchanger. It has a multilayer grating structure in which each layer is offset from the adjacent layer by half a cell which has an opening along both axes perpendicular to the flow axis. Each layer is a composite structure of two sublayers, one of a high thermal conductivity material and another of a low thermal conductivity material. When a hot fluid flows through the cell, heat from the fluid is transferred to the cell wells, and stored there. When the fluid flow reverses direction, heat is transferred from the cell walls back to the fluid.

A third type of regenerator is called a "Rothemuhle" regenerator. This type has a fixed matrix in a disk shape, and streams of fluid are ducted through rotating hoods. The Rothemuhle regenerator is used as an air preheater in some power generating plants. The thermal design of this regenerator is the same as of other types of regenerators.[citation needed]

Biology

We use our nose and throat as a regenerative heat exchanger when we breathe. The cooler air coming in is warmed, so that it reaches the lungs as warm air. On the way back out, this warmed air deposits much of its heat back onto the sides of the nasal passages, so that these passages are then ready to warm the next batch of air coming in.

Cryogenics

Regenerator heat exchangers are made up of materials with high volumetric heat capacity and low thermal conductivity in the longitudinal (flow) direction. At cryogenic (very low) temperatures around 20 K, the specific heat of metals are low, and so a regenerator must be larger for a given heat load.

Advantages of regenerators

The advantages of a regenerator over a recuperating (counter-flowing) heat exchanger is that it has a much higher surface area for a given volume, which provides a reduced exchanger volume for a given energy density, effectiveness and pressure drop. This makes a regenerator more economical in terms of materials and manufacturing, compared to an equivalent recuperator.

The design of inlet and outlet headers used to distribute hot and cold fluids in the matrix is much simpler in counter flow regenerators than recuperators. The reason behind this is that both streams flow in different sections for a rotary regenerator and one fluid enters and leaves one matrix at a time in a fixed-matrix regenerator. Furthermore flow sectors for hot and cold fluids in rotary regenerators can be designed to optimize pressure drop in the fluids. The matrix surfaces of regenerators also have self-cleaning characteristics, reducing fluid-side fouling and corrosion. Finally properties such as small surface density and counter-flow arrangement of regenerators make it ideal for gas-gas heat exchange applications requiring effectiveness exceeding 85%. The heat transfer coefficient is much lower for gases than for liquids, thus the enormous surface area in a regenerator greatly increases heat transfer.

Disadvantages of regenerators

The major disadvantage of a regenerator is that there is always some mixing of the fluid streams, and they can not be completely separated.[citation needed] There is an unavoidable carryover of a small fraction of one fluid stream into the other. In the rotary regenerator, the carryover fluid is trapped inside the radial seal and in the matrix, and in a fixed-matrix regenerator, the carryover fluid is the fluid that remains in the void volume of the matrix. This small fraction will mix with the other stream in the following half-cycle. Therefore regenerators are only used when it is acceptable for the two fluid streams to be mixed. Mixed flow is common for gas-to-gas heat and/or energy transfer applications, and less common in liquid or phase-changing fluids since fluid contamination is often prohibited with liquid flows.

See also

References


Wikimedia Foundation. 2010.

Игры ⚽ Поможем написать реферат

Look at other dictionaries:

  • Heat exchanger — An interchangeable plate heat exchanger Tubular heat exchan …   Wikipedia

  • heat exchanger — a device for transferring the heat of one substance to another, as from the exhaust gases to the incoming air in a regenerative furnace. [1900 05] * * * Any of several devices that transfer heat from a hot to a cold fluid. In many engineering… …   Universalium

  • Regenerative cooling — is a method of cooling gases in which compressed gas is cooled by allowing it to expand and and thereby taking heat from the surroundings, the cooled expanded gas then passes through a heat exchanger where it cools the incoming compressed gas.… …   Wikipedia

  • Stirling engine — Alpha type Stirling engine. There are two cylinders. The expansion cylinder (red) is maintained at a high temperature while the compression cylinder (blue) is cooled. The passage between the two cylinders contains the regenerator …   Wikipedia

  • Countercurrent exchange — Counter heat current exchange: Note the gradually declining differential and that the once hot and cold streams exit at the reversed temperature difference; the hotter entering stream becomes the exiting cooler stream and vice versa.… …   Wikipedia

  • Multi-stage flash distillation — Water desalination Methods Distillation Multi stage flash distillation (MSF) Multiple effect distillation (MED|ME) Vapor compression (VC) Ion exchange Membrane processes Electrodialysis reversal (EDR) Reverse osmosis (RO) Nanofiltration (NF)… …   Wikipedia

  • Economizer — Economizers, or in British English economisers, are mechanical devices intended to reduce energy consumption, or to perform another useful function like preheating a fluid. The term economizer is used for other purposes as well. Boiler,… …   Wikipedia

  • Recuperator — A recuperator is a special purpose counter flow heat exchanger used to recover waste heat from exhaust gases. In many types of processes, combustion is used to generate heat, and the recuperator serves to recuperate, or reclaim this heat, in… …   Wikipedia

  • Régénérateur — Un régénérateur, ou parfois récupérateur, est un dispositif permettant de récupérer de l énergie thermique, par exemple au sein d un moteur Stirling. Il s agit donc d un accumulateur de chaleur. C est l invention du récupérateur par Robert… …   Wikipédia en Français

  • регенеративный теплообменник — — [А.С.Гольдберг. Англо русский энергетический словарь. 2006 г.] Тематики энергетика в целом EN heat recovery exchangerHRXregenerative heat exchangerRHX …   Справочник технического переводчика

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”