IEC 60870-5-101

IEC 60870-5-101

IEC 60870-5-101 (IEC101) is an international standard prepared by TC57 for power system monitoring, control & associated communications. This is completely compatible with IEC 60870-5-1 to IEC 60870-5-5 standards and uses standard asynchronous serial tele-control channel interface between DTE and DCE. The standard is suitable for multiple configurations like point-to-point, star, mutidropped etc.

Features

* Supports unbalanced (master initiated message) & balanced (master/slave initiated message) modes of data transfer.

* Link address and ASDU addresses are provided for classifying the end station and different sectors under the same.

* Data is classified into different information objects and each information object is provided with a specific address.

* Facility to classify the data into high priority (class-1) and low priority (class-2) and transfer the same using separate mechanisms.

* Possibility of classifying the data into different groups (1-16) to get the data according to the group by issuing specific group interrogation commands from the master & obtaining data under all the groups by issuing a general interrogation.

* Cyclic & Spontaneous data updating schemes are provided.

* Facility for time synchronization

* Schemes for transfer of files

Types Supported

* Single indication without / with 24 / with 56 bit timestamps.
* Double indication without / with 24 / with 56 bit timestamps.
* Step position information without / with 24 / with 56 bit timestamps.
* Measured value – normalized, scaled, short floating point without / with timestamps.
* Bitstring of 32 bit without / with timestamps.
* Integrated totals (counters) without / with timestamps.
* Packed events (start & tripping ) of protection equipments
* Single commands
* Double commands
* Regulating step command
* Set point commands of various data formats
* Bitstring commands
* Interrogation commands
* Clock synchronization & delay acquisition commands
* Test & reset commands

ee also

* IEC 60870-5
* IEC 60870-5-104
* IEC 60870-5-103
* IEC 61850
* DNP3

External links

* [http://www.trianglemicroworks.com/iec60870-5/index.htm IEC 60870-5 User Group Mail list]

* [http://www.trianglemicroworks.com/documents/DNPvs870.pdf Comparison of DNP and IEC 60870-5]

* [http://www.kalkitech.com/defaultpsoln.htm?gclid=CN2W4ImSi4wCFQK0TAodLT4k8w Communication Protocols for Energy Automation]

* [http://www.trianglemicroworks.com/ProductPage.htm Commercially available IEC 60870-5-101 Source Code, OPC Client/Server, Protocol Gateway, and Test Tools]

* [http://www.kalkitech.com/iec.htm IEC 60870-5-101 Solutions]

* [http://www.kalkitech.com/protocolgateways.htm IEC 60870-5-101 Protocol Converter & Gateway]

* [http://www.proscada.com/IEC_870.htm IEC 60870-5-101 OPC Server & middle ware]


Wikimedia Foundation. 2010.

Игры ⚽ Нужно сделать НИР?

Look at other dictionaries:

  • IEC 60870-5-101 — IEC 101 (IEC 60870 5 101) es una norma internacional preparada por TC57 para la monitorización de los sistemas de energía, sistemas de control y sus comunicaciones asociadas. Es totalmente compatible con las normas IEC 60870 5 1 y IEC 60870 5 5 y …   Wikipedia Español

  • IEC 60870-5-101 — DIN EN 60870 Bereich Netztechnik Regelt Fernwirkeinrichtungen und systeme (mehrere Teile) Kurzbeschreibung …   Deutsch Wikipedia

  • IEC 60870-5 — provides a communication profile for sending basic telecontrol messages between two systems, which uses permanent directly connected data circuits between the systems. The IEC Technical Committee 57 (Working Group 03) have developed a protocol… …   Wikipedia

  • IEC 60870-5-104 — (IEC 104) protocol is an extension of IEC 101 protocol with the changes in transport, network, link physical layer services to suit the complete network access. The standard uses an open TCP/IP interface to network to have connectivity to the LAN …   Wikipedia

  • IEC 60870-5-103 — [IEC103] is a standard prepared by International Electrotechnical Commission Technical committee 57 for power system control and associated communications. It defines a companion standard that enables interoperability between protection equipment …   Wikipedia

  • IEC 60870 — DIN EN 60870 Bereich Netztechnik Titel Fernwirkeinrichtungen und systeme (mehrere Teile) Letzte Ausgabe …   Deutsch Wikipedia

  • IEC 60870-5 — DIN EN 60870 Bereich Netztechnik Regelt Fernwirkeinrichtungen und systeme (mehrere Teile) Kurzbeschreibung …   Deutsch Wikipedia

  • IEC 60870-5-102 — DIN EN 60870 Bereich Netztechnik Regelt Fernwirkeinrichtungen und systeme (mehrere Teile) Kurzbeschreibung …   Deutsch Wikipedia

  • IEC 60870-5-103 — DIN EN 60870 Bereich Netztechnik Regelt Fernwirkeinrichtungen und systeme (mehrere Teile) Kurzbeschreibung …   Deutsch Wikipedia

  • IEC 60870-5-104 — DIN EN 60870 Bereich Netztechnik Regelt Fernwirkeinrichtungen und systeme (mehrere Teile) Kurzbeschreibung …   Deutsch Wikipedia

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”