Climate Savers Computing Initiative

Climate Savers Computing Initiative

The Climate Savers Computing Initiative is a nonprofit group of consumers, businesses and conservation organizations dedicated to promoting smart technologies that can improve the power efficiency and reduce the energy consumption of computers. Formed in 2007, it is based in Portland, Oregon.[1]

Participating manufacturers commit to producing products that meet specified power-efficiency targets, and members commit to purchasing power-efficient computing products.

By 2010, the initiative seeks to reduce energy consumption by computers by 50 percent and reduce global CO2 emissions from the operation of computers by 54 million tons a year.[2]

Contents

Goal

The goal of the new environmental effort is to save energy and reduce greenhouse gas emissions by setting targets for energy-efficient computers and components, and promoting the adoption of energy-efficient computers and power management tools globally.

The typical desktop PC wastes more than half of the power it draws from a power outlet.[3] Servers typically waste 30-40% of the power they consume. This energy is wasted as heat. As a result, offices, homes, and data centers have increased demands on air conditioning which in turn increases energy requirements and associated costs.

By increasing the effectiveness of power-management features in computers as well as implementing these features and aggressive power-management policies, the average business desktop can save 60% of the electricity consumed, with no compromise to productivity. These results combat climate change and cut costs. With individual member and company participation, this effort may lead to a 50% reduction in power consumption by computers by 2010, and committed participants could collectively save $5.5 billion in energy costs and 54 million tons of CO2 emissions a year.[4] That is the equivalent of taking 11 million cars off the road every year.

Participants in the Climate Savers Computing Initiative represent both the demand and supply side of the computer industry, including computer manufacturers and chip makers, as well as environmental groups, energy companies, retailers, government agencies and more. Members of the initiative include Intel Corporation, Google, Dell, EDS, the United States Environmental Protection Agency‎ (EPA), Hewlett-Packard, Lenovo, Microsoft, Pacific Gas and Electric Company (PG&E), World Wildlife Fund and others.

Specifications

The Climate Savers Computing Initiative operates in a manner similar to the U.S. Government’s Energy Star program. It is intended to promote both the deployment of existing technologies and investment in new energy-efficiency technologies. The Energy Star 4.0 standard for desktops, laptops, and workstations, which took effect in July 2007, requires power supplies to be at least 80 percent efficient for most of their load range. In addition, it puts limits on the energy used by devices when inactive and requires systems to be shipped with power management features enabled.

PCs

The Initiative starts with the 2007 Energy Star requirements for desktops, laptops and workstations (including monitors), and gradually increases the efficiency requirements over the next four years, as follows:

  1. From July 2007 through June 2008, PCs must meet the Energy Star requirements. This means 80 percent minimum efficiency for the power supply unit (PSU) at 20 percent, 50 percent, and 100 percent of rated output, a power factor of at least 0.9 at 100 percent of rated output, and meeting the maximum power requirements in standby, sleep, and idle modes.
  2. From July 2008 through June 2009 the standard increases to 85 percent minimum efficiency for the PSU at 50 percent of rated output (and 82 percent minimum efficiency at 20 percent and 100 percent of rated output). Equivalent to 80 PLUS Bronze level.
  3. From July 2009 through June 2010, the standard increases to 88 percent minimum efficiency for the PSU at 50 percent of rated output (and 85 percent minimum efficiency at 20 percent and 100 percent of rated output). Equivalent to 80 PLUS Silver level.
  4. From July 2010 through June 2011, the standard increases to 90 percent minimum efficiency for the PSU at 50 percent of rated output (and 87 percent minimum efficiency at 20 percent and 100 percent of rated output). Equivalent to 80 PLUS Gold level.

Servers

In addition, the Initiative sets the following high-efficiency targets for volume servers (1U/2U single- and dual-socket servers):

  1. From July 2007 through June 2008, volume servers must have 85 percent minimum efficiency for the power supply unit (PSU) at 50 percent of rated output (and 81 percent minimum efficiency at 20 percent and 100 percent of rated output), and power factor of at least 0.9 at 100 percent of rated output.
  2. From July 2008 through June 2009 the standard increases to 89 percent minimum efficiency for the PSU at 50 percent of rated output (and 85 percent minimum efficiency at 20 percent and 100 percent of rated output).
  3. From July 2009 through June 2010, the standard increases to 92 percent minimum efficiency for the PSU at 50 percent of rated output (and 88 percent minimum efficiency at 20 percent and 100 percent of rated output.

Relevant links

See also

References

  1. ^ Sustainable Business Oregon (2010-07-27). "Study: IT sector cuts CO2 emissions by 32M metric tons". Portland Business Journal. http://www.sustainablebusinessoregon.com/articles/2010/07/study_it_sector_cuts_co2_emissions_by_32m_metric_tons.html. Retrieved 2010-07-27. 
  2. ^ This reduction in emissions is calculated based on IDC projections of desktop and server volumes in the years 2007-2011, using a baseline of 295 kWh/year energy consumption for a typical desktop in the first half of 2007, and assuming market penetration of 60% of desktop units shipped in 2010 being Energy Star, 25% meeting the 85% PSU efficiency standard, 10% meeting the 88% standard, and 5% meeting the 90% standard; it also assumes that 80% of desktop PCs shipped in 2010 use power management features. Under these assumptions, total power consumption for PCs shipped in 2010 will be reduced by over 50%, for a total savings of 62 billion kWh in 2010, worth over $5.5 billion (at an average cost of $0.0885/kWh ). Note: the total savings in 2010 is based on power consumed by units shipped in 2007, 2008, 2009, and 2010.
  3. ^ Based on IDC projections of desktop and server units shipped, a baseline of typical desktop and server power consumption in the first half of 2007, and an average cost of $0.0885/KW.
  4. ^ Based on IDC projections of desktop and server units shipped, a baseline of typical desktop and server power consumption in the first half of 2007, and an average cost of $0.0885/KW.

External links


Wikimedia Foundation. 2010.

Игры ⚽ Поможем решить контрольную работу

Look at other dictionaries:

  • Climate Savers Computing Initiative — Le Climate Savers Computing Initiative est un groupe à but non lucratif de consommateurs, d entreprises et d organisations non gouvernementales qui cherchent à promouvoir les techniques propres de nature à améliorer l efficacité énergétique et à… …   Wikipédia en Français

  • Green computing — is the study and practice of using computing resources efficiently. The primary objective of such a program is to account for the triple bottom line, an expanded spectrum of values and criteria for measuring organizational (and societal) success …   Wikipedia

  • Green computing — L expression anglophone « Green computing » (ou encore « green information technology », en abrégé « green IT ») signifie en français mot à mot « informatique verte », plus largement « informatique éco …   Wikipédia en Français

  • Informatique durable — L informatique a été pendant longtemps considérée comme une industrie « propre », s étant retranchée avec les technologies de l information et de la communication (TIC) derrière des slogans tels que « produits immatériels,… …   Wikipédia en Français

  • Faronics — Die Faronics Corporation ist ein privat geführtes Softwareunternehmen mit Niederlassungen in Vancouver, British Columbia, Kanada, San Ramon, Kalifornien, USA, und Bracknell, Großbritannien. Die Produkte von Faronics finden vorwiegenden Einsatz in …   Deutsch Wikipedia

  • 80 PLUS — is an initiative to promote more electrical energy efficient computer power supply units (PSU). It certifies products that have more than 80% energy efficiency at 20%, 50% and 100% of rated load, and a power factor of 0.9 or greater at 100%… …   Wikipedia

  • Loi de Moore — Croissance du nombre de transistors dans les microprocesseurs Intel par rapport à la loi de Moore. En vert, la fausse hypothèse voulant que ce nombre double tous les 18 mois Les lois de Moore sont des lois empiriques. Elles ont trait à l… …   Wikipédia en Français

  • Politique environnementale des États-Unis — Cet article décrit la politique environnementale des États Unis d Amérique, c est à dire l ensemble des lois et des décisions gouvernementales ayant des conséquences sur l environnement. « Le secteur de la gestion de l environnement fait des …   Wikipédia en Français

  • Efficient energy use — Energy efficiency redirects here. For energy efficiency as a ratio in physics, see Energy conversion efficiency. Efficient energy use, sometimes simply called energy efficiency, is using less energy to provide the same level of energy service. An …   Wikipedia

  • Adaptation au changement climatique — L’adaptation aux changements climatiques ou au dérèglement climatique désigne les stratégies, initiatives et mesures individuelles ou collectives (entreprises, associations, collectivités, etc.) visant, par des mesures adaptées, à réduire la… …   Wikipédia en Français

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”