Inductively Coupled Plasma Emission Spectrometry

Inductively Coupled Plasma Emission Spectrometry

Inductively Coupled Plasma Emission Spectrometry

A test method of quantitative identification of the elements, Aluminium, Silicon, Sodium, Vanadium, Nickel, Iron, Calcium, Zinc and Phosphorus in residual fuel oils.

A weighted test sample is prepared first by Ashing. The residue is fused with a buffer and diluted with water. The solution is then aspirated in the plasma if the Inductively Coupled Plasma Emission Spectrometer (ICPES) and the emission radiation of the resonance lines of the elements under analysis is measured and compared to a calibration curve constructed by standard calibration solutions.

This method of elements determination can also be performed with the Atomic absorption spectroscopy AAS.

Mechanism

The ICP-OES is composed of two parts. The ICP and the optical spectrometer. The ICP torch consists of 3 concentric quartz glass tubes. A water cooled coil of a radio frequency (RF) generator surrounds part of the torch. Argon gas is typically used to create the plasma.

When the torch is turned on, an intense magnetic field from the RF generator is turned on. The argon gas flowing through is ignited with a Tesla unit (typically a copper strip on the outside of the tube). The argon gas is ionized in this field and flows in a particular rotationally symmetrically pattern towards the magnetic field of the RF coil. A stable, high temperature plasma of about 7000K is then generated as the result of the inelastic collisions created between the neutral argon atoms and the charged particles.

A peristaltic pump delivers an aqueous or organic sample into a nebulizer where atomized and introduced directly inside the plasma flame. The sample immediately collides with the electrons and other charged ions in the plasma and is broken down into charged ions. The various molecules break up into their respective atoms which then lose electrons and recombine repeatedly in the plasma, giving off the characteristic wavelengths of the elements involved.

A shear gas, typically nitrogen or dry compressed air is used to 'cut' the plasma flame at a specific spot. 1 or 2 transfer lenses are then used to focus the emitted light on a diffraction grating where it is separated into its component radiation in the optical spectrometer. The light intensity is then measured with a photomultiplier tube at the specific wavelength for each element line involved.

The intensity of each line is then compared to previous measured intensities of known concentrations of the element and its concentration is then computed by extrapolation along the calibration line.

ee also

*Atomic absorption spectroscopy
*Ashing


Wikimedia Foundation. 2010.

Игры ⚽ Поможем сделать НИР

Look at other dictionaries:

  • Inductively coupled plasma mass spectrometry — ICP MS Instrument Acronym ICP MS Classification Mass spectrometry Analytes atomic and polyatomic species in plasma, with exceptions; usually inte …   Wikipedia

  • Inductively coupled plasma atomic emission spectroscopy — (ICP AES), also referred to as inductively coupled plasma optical emission spectrometry (ICP OES), is an analytical technique used for the detection of trace metals. It is a type of emission spectroscopy that uses the inductively coupled plasma… …   Wikipedia

  • Inductively coupled plasma — An inductively coupled plasma (ICP) is a type of plasma source in which the energy is supplied by electrical currents which are produced by electromagnetic induction, that is, by time varying magnetic fields. [A. Montaser and D. W. Golightly, eds …   Wikipedia

  • Plasma-Physik — Plasma in einer Plasmalampe. Datei:Gerds plasma.jpg magnetisch verformtes Plasma Sonne …   Deutsch Wikipedia

  • Plasma (Physik) — Plasma in einer Plasmalampe Magnetisch verformtes Plasma …   Deutsch Wikipedia

  • Plasma (physics) — For other uses, see Plasma. Plasma lamp, illustrating some of the more complex phenomena of a plasma, including filamentation. The colors are a result of relaxation of electrons in excited states to lower energy states after they have recombined… …   Wikipedia

  • Mass spectrometry — (MS) is an analytical technique that measures the mass to charge ratio of charged particles.[1] It is used for determining masses of particles, for determining the elemental composition of a sample or molecule, and for elucidating the chemical… …   Wikipedia

  • Optical Emission Spectrometer — Atomspektroskopie (auch Atomspektrometrie) ist ein Sammelbegriff für spektroskopische Verfahren, die zur quantitativen und qualitativen Bestimmung von Elementen eingesetzt werden. Die Atomspektroskopie ist ein Teilbereich der Analytischen Chemie …   Deutsch Wikipedia

  • Atomic emission spectroscopy — (AES) is a method of chemical analysis that uses the intensity of light emitted from a flame, plasma, arc, or spark at a particular wavelength to determine the quantity of an element in a sample. The wavelength of the atomic spectral line gives… …   Wikipedia

  • mass spectrometry — or mass spectroscopy Analytic technique by which chemical substances are identified by sorting gaseous ions by mass using electric and magnetic fields. A mass spectrometer uses electrical means to detect the sorted ions, while a mass spectrograph …   Universalium

Share the article and excerpts

Direct link
Do a right-click on the link above
and select “Copy Link”